hwmon: Add support for Lineage Compact Power Line PEM devices
This patch adds support for hardware monitoring of Lineage Compact Power Line
Power Entry Modules.
Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon/lineage-pem')
-rw-r--r-- | Documentation/hwmon/lineage-pem | 77 |
1 files changed, 77 insertions, 0 deletions
diff --git a/Documentation/hwmon/lineage-pem b/Documentation/hwmon/lineage-pem new file mode 100644 index 000000000000..2ba5ed126858 --- /dev/null +++ b/Documentation/hwmon/lineage-pem | |||
@@ -0,0 +1,77 @@ | |||
1 | Kernel driver lineage-pem | ||
2 | ========================= | ||
3 | |||
4 | Supported devices: | ||
5 | * Lineage Compact Power Line Power Entry Modules | ||
6 | Prefix: 'lineage-pem' | ||
7 | Addresses scanned: - | ||
8 | Documentation: | ||
9 | http://www.lineagepower.com/oem/pdf/CPLI2C.pdf | ||
10 | |||
11 | Author: Guenter Roeck <guenter.roeck@ericsson.com> | ||
12 | |||
13 | |||
14 | Description | ||
15 | ----------- | ||
16 | |||
17 | This driver supports various Lineage Compact Power Line DC/DC and AC/DC | ||
18 | converters such as CP1800, CP2000AC, CP2000DC, CP2100DC, and others. | ||
19 | |||
20 | Lineage CPL power entry modules are nominally PMBus compliant. However, most | ||
21 | standard PMBus commands are not supported. Specifically, all hardware monitoring | ||
22 | and status reporting commands are non-standard. For this reason, a standard | ||
23 | PMBus driver can not be used. | ||
24 | |||
25 | |||
26 | Usage Notes | ||
27 | ----------- | ||
28 | |||
29 | This driver does not probe for Lineage CPL devices, since there is no register | ||
30 | which can be safely used to identify the chip. You will have to instantiate | ||
31 | the devices explicitly. | ||
32 | |||
33 | Example: the following will load the driver for a Lineage PEM at address 0x40 | ||
34 | on I2C bus #1: | ||
35 | $ modprobe lineage-pem | ||
36 | $ echo lineage-pem 0x40 > /sys/bus/i2c/devices/i2c-1/new_device | ||
37 | |||
38 | All Lineage CPL power entry modules have a built-in I2C bus master selector | ||
39 | (PCA9541). To ensure device access, this driver should only be used as client | ||
40 | driver to the pca9541 I2C master selector driver. | ||
41 | |||
42 | |||
43 | Sysfs entries | ||
44 | ------------- | ||
45 | |||
46 | All Lineage CPL devices report output voltage and device temperature as well as | ||
47 | alarms for output voltage, temperature, input voltage, input current, input power, | ||
48 | and fan status. | ||
49 | |||
50 | Input voltage, input current, input power, and fan speed measurement is only | ||
51 | supported on newer devices. The driver detects if those attributes are supported, | ||
52 | and only creates respective sysfs entries if they are. | ||
53 | |||
54 | in1_input Output voltage (mV) | ||
55 | in1_min_alarm Output undervoltage alarm | ||
56 | in1_max_alarm Output overvoltage alarm | ||
57 | in1_crit Output voltage critical alarm | ||
58 | |||
59 | in2_input Input voltage (mV, optional) | ||
60 | in2_alarm Input voltage alarm | ||
61 | |||
62 | curr1_input Input current (mA, optional) | ||
63 | curr1_alarm Input overcurrent alarm | ||
64 | |||
65 | power1_input Input power (uW, optional) | ||
66 | power1_alarm Input power alarm | ||
67 | |||
68 | fan1_input Fan 1 speed (rpm, optional) | ||
69 | fan2_input Fan 2 speed (rpm, optional) | ||
70 | fan3_input Fan 3 speed (rpm, optional) | ||
71 | |||
72 | temp1_input | ||
73 | temp1_max | ||
74 | temp1_crit | ||
75 | temp1_alarm | ||
76 | temp1_crit_alarm | ||
77 | temp1_fault | ||