aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/dcdbas.txt
diff options
context:
space:
mode:
authorDmitry Torokhov <dtor_core@ameritech.net>2005-09-09 21:14:47 -0400
committerDmitry Torokhov <dtor_core@ameritech.net>2005-09-09 21:14:47 -0400
commitd344c5e0856ad03278d8700b503762dbc8b86e12 (patch)
treea6d893a643470a3c2580a58f3228a55fa1fd1d82 /Documentation/dcdbas.txt
parent010988e888a0abbe7118635c1b33d049caae6b29 (diff)
parent87fc767b832ef5a681a0ff9d203c3289bc3be2bf (diff)
Manual merge with Linus
Diffstat (limited to 'Documentation/dcdbas.txt')
-rw-r--r--Documentation/dcdbas.txt91
1 files changed, 91 insertions, 0 deletions
diff --git a/Documentation/dcdbas.txt b/Documentation/dcdbas.txt
new file mode 100644
index 000000000000..e1c52e2dc361
--- /dev/null
+++ b/Documentation/dcdbas.txt
@@ -0,0 +1,91 @@
1Overview
2
3The Dell Systems Management Base Driver provides a sysfs interface for
4systems management software such as Dell OpenManage to perform system
5management interrupts and host control actions (system power cycle or
6power off after OS shutdown) on certain Dell systems.
7
8Dell OpenManage requires this driver on the following Dell PowerEdge systems:
9300, 1300, 1400, 400SC, 500SC, 1500SC, 1550, 600SC, 1600SC, 650, 1655MC,
10700, and 750. Other Dell software such as the open source libsmbios project
11is expected to make use of this driver, and it may include the use of this
12driver on other Dell systems.
13
14The Dell libsmbios project aims towards providing access to as much BIOS
15information as possible. See http://linux.dell.com/libsmbios/main/ for
16more information about the libsmbios project.
17
18
19System Management Interrupt
20
21On some Dell systems, systems management software must access certain
22management information via a system management interrupt (SMI). The SMI data
23buffer must reside in 32-bit address space, and the physical address of the
24buffer is required for the SMI. The driver maintains the memory required for
25the SMI and provides a way for the application to generate the SMI.
26The driver creates the following sysfs entries for systems management
27software to perform these system management interrupts:
28
29/sys/devices/platform/dcdbas/smi_data
30/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
31/sys/devices/platform/dcdbas/smi_data_buf_size
32/sys/devices/platform/dcdbas/smi_request
33
34Systems management software must perform the following steps to execute
35a SMI using this driver:
36
371) Lock smi_data.
382) Write system management command to smi_data.
393) Write "1" to smi_request to generate a calling interface SMI or
40 "2" to generate a raw SMI.
414) Read system management command response from smi_data.
425) Unlock smi_data.
43
44
45Host Control Action
46
47Dell OpenManage supports a host control feature that allows the administrator
48to perform a power cycle or power off of the system after the OS has finished
49shutting down. On some Dell systems, this host control feature requires that
50a driver perform a SMI after the OS has finished shutting down.
51
52The driver creates the following sysfs entries for systems management software
53to schedule the driver to perform a power cycle or power off host control
54action after the system has finished shutting down:
55
56/sys/devices/platform/dcdbas/host_control_action
57/sys/devices/platform/dcdbas/host_control_smi_type
58/sys/devices/platform/dcdbas/host_control_on_shutdown
59
60Dell OpenManage performs the following steps to execute a power cycle or
61power off host control action using this driver:
62
631) Write host control action to be performed to host_control_action.
642) Write type of SMI that driver needs to perform to host_control_smi_type.
653) Write "1" to host_control_on_shutdown to enable host control action.
664) Initiate OS shutdown.
67 (Driver will perform host control SMI when it is notified that the OS
68 has finished shutting down.)
69
70
71Host Control SMI Type
72
73The following table shows the value to write to host_control_smi_type to
74perform a power cycle or power off host control action:
75
76PowerEdge System Host Control SMI Type
77---------------- ---------------------
78 300 HC_SMITYPE_TYPE1
79 1300 HC_SMITYPE_TYPE1
80 1400 HC_SMITYPE_TYPE2
81 500SC HC_SMITYPE_TYPE2
82 1500SC HC_SMITYPE_TYPE2
83 1550 HC_SMITYPE_TYPE2
84 600SC HC_SMITYPE_TYPE2
85 1600SC HC_SMITYPE_TYPE2
86 650 HC_SMITYPE_TYPE2
87 1655MC HC_SMITYPE_TYPE2
88 700 HC_SMITYPE_TYPE3
89 750 HC_SMITYPE_TYPE3
90
91