aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorMatt LaPlante <kernel1@cyberdogtech.com>2006-10-03 16:36:44 -0400
committerAdrian Bunk <bunk@stusta.de>2006-10-03 16:36:44 -0400
commitcab00891c5489cb6d0cde0a55d39bd5f2871fa70 (patch)
tree0dc810a15ad02dc76939b6ea021a4a24794561bb
parent44c09201a4178e08ed1c8cc37e7aea0683888f0a (diff)
Still more typo fixes
Signed-off-by: Adrian Bunk <bunk@stusta.de>
-rw-r--r--arch/arm/mach-s3c2410/Kconfig2
-rw-r--r--arch/ppc/platforms/85xx/Kconfig14
-rw-r--r--arch/xtensa/Kconfig4
-rw-r--r--drivers/infiniband/ulp/ipoib/Kconfig2
-rw-r--r--drivers/media/video/cx88/Kconfig2
-rw-r--r--drivers/net/Kconfig2
-rw-r--r--drivers/pci/hotplug/Kconfig2
-rw-r--r--drivers/usb/atm/Kconfig2
-rw-r--r--drivers/usb/gadget/Kconfig2
-rw-r--r--drivers/video/Kconfig2
-rw-r--r--fs/Kconfig2
-rw-r--r--fs/cifs/README6
-rw-r--r--net/ipv4/Kconfig2
-rw-r--r--net/ipv4/ipvs/Kconfig2
-rw-r--r--security/selinux/Kconfig2
15 files changed, 24 insertions, 24 deletions
diff --git a/arch/arm/mach-s3c2410/Kconfig b/arch/arm/mach-s3c2410/Kconfig
index df37594c30f8..63965c78de8c 100644
--- a/arch/arm/mach-s3c2410/Kconfig
+++ b/arch/arm/mach-s3c2410/Kconfig
@@ -13,7 +13,7 @@ config MACH_ANUBIS
13 bool "Simtec Electronics ANUBIS" 13 bool "Simtec Electronics ANUBIS"
14 select CPU_S3C2440 14 select CPU_S3C2440
15 help 15 help
16 Say Y gere if you are using the Simtec Electronics ANUBIS 16 Say Y here if you are using the Simtec Electronics ANUBIS
17 development system 17 development system
18 18
19config MACH_OSIRIS 19config MACH_OSIRIS
diff --git a/arch/ppc/platforms/85xx/Kconfig b/arch/ppc/platforms/85xx/Kconfig
index 7ddd331a7145..6f2d0add7de6 100644
--- a/arch/ppc/platforms/85xx/Kconfig
+++ b/arch/ppc/platforms/85xx/Kconfig
@@ -24,12 +24,12 @@ config MPC8540_ADS
24config MPC8548_CDS 24config MPC8548_CDS
25 bool "Freescale MPC8548 CDS" 25 bool "Freescale MPC8548 CDS"
26 help 26 help
27 This option enablese support for the MPC8548 CDS evaluation board. 27 This option enables support for the MPC8548 CDS evaluation board.
28 28
29config MPC8555_CDS 29config MPC8555_CDS
30 bool "Freescale MPC8555 CDS" 30 bool "Freescale MPC8555 CDS"
31 help 31 help
32 This option enablese support for the MPC8555 CDS evaluation board. 32 This option enables support for the MPC8555 CDS evaluation board.
33 33
34config MPC8560_ADS 34config MPC8560_ADS
35 bool "Freescale MPC8560 ADS" 35 bool "Freescale MPC8560 ADS"
@@ -51,22 +51,22 @@ config STX_GP3
51config TQM8540 51config TQM8540
52 bool "TQ Components TQM8540" 52 bool "TQ Components TQM8540"
53 help 53 help
54 This option enablese support for the TQ Components TQM8540 board. 54 This option enables support for the TQ Components TQM8540 board.
55 55
56config TQM8541 56config TQM8541
57 bool "TQ Components TQM8541" 57 bool "TQ Components TQM8541"
58 help 58 help
59 This option enablese support for the TQ Components TQM8541 board. 59 This option enables support for the TQ Components TQM8541 board.
60 60
61config TQM8555 61config TQM8555
62 bool "TQ Components TQM8555" 62 bool "TQ Components TQM8555"
63 help 63 help
64 This option enablese support for the TQ Components TQM8555 board. 64 This option enables support for the TQ Components TQM8555 board.
65 65
66config TQM8560 66config TQM8560
67 bool "TQ Components TQM8560" 67 bool "TQ Components TQM8560"
68 help 68 help
69 This option enablese support for the TQ Components TQM8560 board. 69 This option enables support for the TQ Components TQM8560 board.
70 70
71endchoice 71endchoice
72 72
@@ -94,7 +94,7 @@ config MPC8560
94 default y 94 default y
95 95
96config 85xx_PCI2 96config 85xx_PCI2
97 bool "Supprt for 2nd PCI host controller" 97 bool "Support for 2nd PCI host controller"
98 depends on MPC8555_CDS 98 depends on MPC8555_CDS
99 default y 99 default y
100 100
diff --git a/arch/xtensa/Kconfig b/arch/xtensa/Kconfig
index 848f173db257..c1e69a1f92a4 100644
--- a/arch/xtensa/Kconfig
+++ b/arch/xtensa/Kconfig
@@ -206,7 +206,7 @@ source "drivers/pci/hotplug/Kconfig"
206 206
207endmenu 207endmenu
208 208
209menu "Exectuable file formats" 209menu "Executable file formats"
210 210
211# only elf supported 211# only elf supported
212config KCORE_ELF 212config KCORE_ELF
@@ -241,7 +241,7 @@ menu "Xtensa initrd options"
241 bool "Embed root filesystem ramdisk into the kernel" 241 bool "Embed root filesystem ramdisk into the kernel"
242 242
243config EMBEDDED_RAMDISK_IMAGE 243config EMBEDDED_RAMDISK_IMAGE
244 string "Filename of gziped ramdisk image" 244 string "Filename of gzipped ramdisk image"
245 depends on EMBEDDED_RAMDISK 245 depends on EMBEDDED_RAMDISK
246 default "ramdisk.gz" 246 default "ramdisk.gz"
247 help 247 help
diff --git a/drivers/infiniband/ulp/ipoib/Kconfig b/drivers/infiniband/ulp/ipoib/Kconfig
index d74653d7de1c..c75322d820d4 100644
--- a/drivers/infiniband/ulp/ipoib/Kconfig
+++ b/drivers/infiniband/ulp/ipoib/Kconfig
@@ -26,7 +26,7 @@ config INFINIBAND_IPOIB_DEBUG_DATA
26 bool "IP-over-InfiniBand data path debugging" 26 bool "IP-over-InfiniBand data path debugging"
27 depends on INFINIBAND_IPOIB_DEBUG 27 depends on INFINIBAND_IPOIB_DEBUG
28 ---help--- 28 ---help---
29 This option compiles debugging code into the the data path 29 This option compiles debugging code into the data path
30 of the IPoIB driver. The output can be turned on via the 30 of the IPoIB driver. The output can be turned on via the
31 data_debug_level module parameter; however, even with output 31 data_debug_level module parameter; however, even with output
32 turned off, this debugging code will have some performance 32 turned off, this debugging code will have some performance
diff --git a/drivers/media/video/cx88/Kconfig b/drivers/media/video/cx88/Kconfig
index 51d68f32aa06..0f9d96963618 100644
--- a/drivers/media/video/cx88/Kconfig
+++ b/drivers/media/video/cx88/Kconfig
@@ -69,6 +69,6 @@ config VIDEO_CX88_VP3054
69 depends on VIDEO_CX88_DVB && DVB_MT352 69 depends on VIDEO_CX88_DVB && DVB_MT352
70 ---help--- 70 ---help---
71 This adds DVB-T support for cards based on the 71 This adds DVB-T support for cards based on the
72 Connexant 2388x chip and the MT352 demodulator, 72 Conexant 2388x chip and the MT352 demodulator,
73 which also require support for the VP-3054 73 which also require support for the VP-3054
74 Secondary I2C bus, such at DNTV Live! DVB-T Pro. 74 Secondary I2C bus, such at DNTV Live! DVB-T Pro.
diff --git a/drivers/net/Kconfig b/drivers/net/Kconfig
index ff8a8c0a26d5..ab92cc794c64 100644
--- a/drivers/net/Kconfig
+++ b/drivers/net/Kconfig
@@ -2115,7 +2115,7 @@ config SKY2
2115 depends on PCI && EXPERIMENTAL 2115 depends on PCI && EXPERIMENTAL
2116 select CRC32 2116 select CRC32
2117 ---help--- 2117 ---help---
2118 This driver supports Gigabit Ethernet adapters based on the the 2118 This driver supports Gigabit Ethernet adapters based on the
2119 Marvell Yukon 2 chipset: 2119 Marvell Yukon 2 chipset:
2120 Marvell 88E8021/88E8022/88E8035/88E8036/88E8038/88E8050/88E8052/ 2120 Marvell 88E8021/88E8022/88E8035/88E8036/88E8038/88E8050/88E8052/
2121 88E8053/88E8055/88E8061/88E8062, SysKonnect SK-9E21D/SK-9S21 2121 88E8053/88E8055/88E8061/88E8062, SysKonnect SK-9E21D/SK-9S21
diff --git a/drivers/pci/hotplug/Kconfig b/drivers/pci/hotplug/Kconfig
index 8a60f391ffcf..6e780db9454d 100644
--- a/drivers/pci/hotplug/Kconfig
+++ b/drivers/pci/hotplug/Kconfig
@@ -157,7 +157,7 @@ config HOTPLUG_PCI_RPA
157 tristate "RPA PCI Hotplug driver" 157 tristate "RPA PCI Hotplug driver"
158 depends on HOTPLUG_PCI && PPC_PSERIES && PPC64 && !HOTPLUG_PCI_FAKE 158 depends on HOTPLUG_PCI && PPC_PSERIES && PPC64 && !HOTPLUG_PCI_FAKE
159 help 159 help
160 Say Y here if you have a a RPA system that supports PCI Hotplug. 160 Say Y here if you have a RPA system that supports PCI Hotplug.
161 161
162 To compile this driver as a module, choose M here: the 162 To compile this driver as a module, choose M here: the
163 module will be called rpaphp. 163 module will be called rpaphp.
diff --git a/drivers/usb/atm/Kconfig b/drivers/usb/atm/Kconfig
index 550ddfa71a43..b450cbaa3a0b 100644
--- a/drivers/usb/atm/Kconfig
+++ b/drivers/usb/atm/Kconfig
@@ -64,7 +64,7 @@ config USB_XUSBATM
64 Say Y here if you have a DSL USB modem not explicitly supported by 64 Say Y here if you have a DSL USB modem not explicitly supported by
65 another USB DSL drivers. In order to use your modem you will need to 65 another USB DSL drivers. In order to use your modem you will need to
66 pass the vendor ID, product ID, and endpoint numbers for transmission 66 pass the vendor ID, product ID, and endpoint numbers for transmission
67 and reception as module parameters. You may need to initialize the 67 and reception as module parameters. You may need to initialize
68 the modem using a user space utility (a firmware loader for example). 68 the modem using a user space utility (a firmware loader for example).
69 69
70 To compile this driver as a module, choose M here: the 70 To compile this driver as a module, choose M here: the
diff --git a/drivers/usb/gadget/Kconfig b/drivers/usb/gadget/Kconfig
index 8e5dd6f29d0b..bbbc82a8336a 100644
--- a/drivers/usb/gadget/Kconfig
+++ b/drivers/usb/gadget/Kconfig
@@ -7,7 +7,7 @@
7# 7#
8# - Host systems (like PCs) need CONFIG_USB (with "A" jacks). 8# - Host systems (like PCs) need CONFIG_USB (with "A" jacks).
9# - Peripherals (like PDAs) need CONFIG_USB_GADGET (with "B" jacks). 9# - Peripherals (like PDAs) need CONFIG_USB_GADGET (with "B" jacks).
10# - Some systems have both kinds of of controller. 10# - Some systems have both kinds of controllers.
11# 11#
12# With help from a special transceiver and a "Mini-AB" jack, systems with 12# With help from a special transceiver and a "Mini-AB" jack, systems with
13# both kinds of controller can also support "USB On-the-Go" (CONFIG_USB_OTG). 13# both kinds of controller can also support "USB On-the-Go" (CONFIG_USB_OTG).
diff --git a/drivers/video/Kconfig b/drivers/video/Kconfig
index 4608a275955f..daaa486159cf 100644
--- a/drivers/video/Kconfig
+++ b/drivers/video/Kconfig
@@ -188,7 +188,7 @@ config FB_ARMCLCD_SHARP_LQ035Q7DB02_HRTFT
188 bool "LogicPD LCD 3.5\" QVGA w/HRTFT IC" 188 bool "LogicPD LCD 3.5\" QVGA w/HRTFT IC"
189 help 189 help
190 This is an implementation of the Sharp LQ035Q7DB02, a 3.5" 190 This is an implementation of the Sharp LQ035Q7DB02, a 3.5"
191 color QVGA, HRTFT panel. The LogicPD device includes an 191 color QVGA, HRTFT panel. The LogicPD device includes
192 an integrated HRTFT controller IC. 192 an integrated HRTFT controller IC.
193 The native resolution is 240x320. 193 The native resolution is 240x320.
194 194
diff --git a/fs/Kconfig b/fs/Kconfig
index deaad99ffadb..68f4561423ff 100644
--- a/fs/Kconfig
+++ b/fs/Kconfig
@@ -1365,7 +1365,7 @@ config SYSV_FS
1365 1365
1366 If you have floppies or hard disk partitions like that, it is likely 1366 If you have floppies or hard disk partitions like that, it is likely
1367 that they contain binaries from those other Unix systems; in order 1367 that they contain binaries from those other Unix systems; in order
1368 to run these binaries, you will want to install linux-abi which is a 1368 to run these binaries, you will want to install linux-abi which is
1369 a set of kernel modules that lets you run SCO, Xenix, Wyse, 1369 a set of kernel modules that lets you run SCO, Xenix, Wyse,
1370 UnixWare, Dell Unix and System V programs under Linux. It is 1370 UnixWare, Dell Unix and System V programs under Linux. It is
1371 available via FTP (user: ftp) from 1371 available via FTP (user: ftp) from
diff --git a/fs/cifs/README b/fs/cifs/README
index 5f0e1bd64fee..432e515431c4 100644
--- a/fs/cifs/README
+++ b/fs/cifs/README
@@ -269,7 +269,7 @@ A partial list of the supported mount options follows:
269 (gid) mount option is specified. For the uid (gid) of newly 269 (gid) mount option is specified. For the uid (gid) of newly
270 created files and directories, ie files created since 270 created files and directories, ie files created since
271 the last mount of the server share, the expected uid 271 the last mount of the server share, the expected uid
272 (gid) is cached as as long as the inode remains in 272 (gid) is cached as long as the inode remains in
273 memory on the client. Also note that permission 273 memory on the client. Also note that permission
274 checks (authorization checks) on accesses to a file occur 274 checks (authorization checks) on accesses to a file occur
275 at the server, but there are cases in which an administrator 275 at the server, but there are cases in which an administrator
@@ -375,7 +375,7 @@ A partial list of the supported mount options follows:
375 the local process on newly created files, directories, and 375 the local process on newly created files, directories, and
376 devices (create, mkdir, mknod). If the CIFS Unix Extensions 376 devices (create, mkdir, mknod). If the CIFS Unix Extensions
377 are not negotiated, for newly created files and directories 377 are not negotiated, for newly created files and directories
378 instead of using the default uid and gid specified on the 378 instead of using the default uid and gid specified on
379 the mount, cache the new file's uid and gid locally which means 379 the mount, cache the new file's uid and gid locally which means
380 that the uid for the file can change when the inode is 380 that the uid for the file can change when the inode is
381 reloaded (or the user remounts the share). 381 reloaded (or the user remounts the share).
@@ -440,7 +440,7 @@ A partial list of the supported mount options follows:
440 create device files and fifos in a format compatible with 440 create device files and fifos in a format compatible with
441 Services for Unix (SFU). In addition retrieve bits 10-12 441 Services for Unix (SFU). In addition retrieve bits 10-12
442 of the mode via the SETFILEBITS extended attribute (as 442 of the mode via the SETFILEBITS extended attribute (as
443 SFU does). In the future the bottom 9 bits of the mode 443 SFU does). In the future the bottom 9 bits of the
444 mode also will be emulated using queries of the security 444 mode also will be emulated using queries of the security
445 descriptor (ACL). 445 descriptor (ACL).
446 sign Must use packet signing (helps avoid unwanted data modification 446 sign Must use packet signing (helps avoid unwanted data modification
diff --git a/net/ipv4/Kconfig b/net/ipv4/Kconfig
index 0adfd88b7b0b..d172a9804448 100644
--- a/net/ipv4/Kconfig
+++ b/net/ipv4/Kconfig
@@ -556,7 +556,7 @@ config TCP_CONG_LP
556 default n 556 default n
557 ---help--- 557 ---help---
558 TCP Low Priority (TCP-LP), a distributed algorithm whose goal is 558 TCP Low Priority (TCP-LP), a distributed algorithm whose goal is
559 to utiliza only the excess network bandwidth as compared to the 559 to utilize only the excess network bandwidth as compared to the
560 ``fair share`` of bandwidth as targeted by TCP. 560 ``fair share`` of bandwidth as targeted by TCP.
561 See http://www-ece.rice.edu/networks/TCP-LP/ 561 See http://www-ece.rice.edu/networks/TCP-LP/
562 562
diff --git a/net/ipv4/ipvs/Kconfig b/net/ipv4/ipvs/Kconfig
index ad52c294d219..891b9355cf96 100644
--- a/net/ipv4/ipvs/Kconfig
+++ b/net/ipv4/ipvs/Kconfig
@@ -204,7 +204,7 @@ config IP_VS_SED
204 connections to the server with the shortest expected delay. The 204 connections to the server with the shortest expected delay. The
205 expected delay that the job will experience is (Ci + 1) / Ui if 205 expected delay that the job will experience is (Ci + 1) / Ui if
206 sent to the ith server, in which Ci is the number of connections 206 sent to the ith server, in which Ci is the number of connections
207 on the the ith server and Ui is the fixed service rate (weight) 207 on the ith server and Ui is the fixed service rate (weight)
208 of the ith server. 208 of the ith server.
209 209
210 If you want to compile it in kernel, say Y. To compile it as a 210 If you want to compile it in kernel, say Y. To compile it as a
diff --git a/security/selinux/Kconfig b/security/selinux/Kconfig
index d62b09843127..23b51047494e 100644
--- a/security/selinux/Kconfig
+++ b/security/selinux/Kconfig
@@ -122,7 +122,7 @@ config SECURITY_SELINUX_ENABLE_SECMARK_DEFAULT
122 well as any conntrack helpers for protocols which you 122 well as any conntrack helpers for protocols which you
123 wish to control. 123 wish to control.
124 124
125 If you are unsure what do do here, select N. 125 If you are unsure what to do here, select N.
126 126
127config SECURITY_SELINUX_POLICYDB_VERSION_MAX 127config SECURITY_SELINUX_POLICYDB_VERSION_MAX
128 bool "NSA SELinux maximum supported policy format version" 128 bool "NSA SELinux maximum supported policy format version"