aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorJuerg Haefliger <juergh@gmail.com>2006-09-24 14:55:34 -0400
committerGreg Kroah-Hartman <gregkh@suse.de>2006-09-28 18:31:16 -0400
commita1fdcb96ee33ba75318476a2a4691147c9f2ad90 (patch)
treeac5d846a5ad4106406b793abacd168075d7e59b8
parent61d0b53363256e87aeb79286be2dc8f62a9d429a (diff)
vt1211: Document module parameters
vt1211: Document module parameters Add a description of the module parameters to the documentation of the vt1211 driver. Signed-off-by: Juerg Haefliger <juergh@gmail.com> Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
-rw-r--r--Documentation/hwmon/vt121124
1 files changed, 21 insertions, 3 deletions
diff --git a/Documentation/hwmon/vt1211 b/Documentation/hwmon/vt1211
index d6d807138195..77fa633b97a8 100644
--- a/Documentation/hwmon/vt1211
+++ b/Documentation/hwmon/vt1211
@@ -16,6 +16,26 @@ Thanks to Joseph Chan and Fiona Gatt from VIA for providing documentation and
16technical support. 16technical support.
17 17
18 18
19Module Parameters
20-----------------
21
22* uch_config: int Override the BIOS default universal channel (UCH)
23 configuration for channels 1-5.
24 Legal values are in the range of 0-31. Bit 0 maps to
25 UCH1, bit 1 maps to UCH2 and so on. Setting a bit to 1
26 enables the thermal input of that particular UCH and
27 setting a bit to 0 enables the voltage input.
28
29* int_mode: int Override the BIOS default temperature interrupt mode.
30 The only possible value is 0 which forces interrupt
31 mode 0. In this mode, any pending interrupt is cleared
32 when the status register is read but is regenerated as
33 long as the temperature stays above the hysteresis
34 limit.
35
36Be aware that overriding BIOS defaults might cause some unwanted side effects!
37
38
19Description 39Description
20----------- 40-----------
21 41
@@ -88,9 +108,7 @@ has a high limit which triggers an alarm if crossed. There is an associated
88hysteresis value with each temperature below which the temperature has to drop 108hysteresis value with each temperature below which the temperature has to drop
89before the alarm is cleared (this is only true for interrupt mode 0). The 109before the alarm is cleared (this is only true for interrupt mode 0). The
90interrupt mode can be forced to 0 in case the BIOS doesn't do it 110interrupt mode can be forced to 0 in case the BIOS doesn't do it
91automatically. For that, the parameter int_mode=0 needs to be supplied when 111automatically. See the 'Module Parameters' section for details.
92loading the driver module. Be aware that overriding BIOS defaults might cause
93some unwanted side effects!
94 112
95All temperature channels except temp2 are external. Temp2 is the VT1211 113All temperature channels except temp2 are external. Temp2 is the VT1211
96internal thermal diode and the driver does all the scaling for temp2 and 114internal thermal diode and the driver does all the scaling for temp2 and