diff options
author | Christof Schmitt <christof.schmitt@de.ibm.com> | 2008-11-04 10:35:10 -0500 |
---|---|---|
committer | James Bottomley <James.Bottomley@HansenPartnership.com> | 2008-11-05 12:47:19 -0500 |
commit | 77fd9494bce3188c20d82e45464ed9b1be83bf98 (patch) | |
tree | fde00a1b349fa77a478aadb62bf91f24e63f257e | |
parent | adc90daffbb454eeae00df92855a88ba79b5b636 (diff) |
[SCSI] zfcp: Wait for port scan to complete when setting adapter online
Attaching a unit immediately after setting the adapter online should
be possible. The problem right now is that the port_scan runs from a
workqueue and has not finished when the set_online call returns and
the sysfs structures for the ports are not available yet. Fix that by
waiting for the port scan to complete.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
-rw-r--r-- | drivers/s390/scsi/zfcp_ccw.c | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/drivers/s390/scsi/zfcp_ccw.c b/drivers/s390/scsi/zfcp_ccw.c index b04038c74786..951a8d409d1d 100644 --- a/drivers/s390/scsi/zfcp_ccw.c +++ b/drivers/s390/scsi/zfcp_ccw.c | |||
@@ -116,7 +116,9 @@ static int zfcp_ccw_set_online(struct ccw_device *ccw_device) | |||
116 | zfcp_erp_adapter_reopen(adapter, ZFCP_STATUS_COMMON_ERP_FAILED, 85, | 116 | zfcp_erp_adapter_reopen(adapter, ZFCP_STATUS_COMMON_ERP_FAILED, 85, |
117 | NULL); | 117 | NULL); |
118 | zfcp_erp_wait(adapter); | 118 | zfcp_erp_wait(adapter); |
119 | goto out; | 119 | up(&zfcp_data.config_sema); |
120 | flush_work(&adapter->scan_work); | ||
121 | return 0; | ||
120 | 122 | ||
121 | out_scsi_register: | 123 | out_scsi_register: |
122 | zfcp_erp_thread_kill(adapter); | 124 | zfcp_erp_thread_kill(adapter); |