diff options
author | Andi Kleen <ak@suse.de> | 2006-07-29 15:42:46 -0400 |
---|---|---|
committer | Linus Torvalds <torvalds@g5.osdl.org> | 2006-07-29 23:59:55 -0400 |
commit | 355540f3338e1408dac98413f05d612a76d4f5e3 (patch) | |
tree | 4e9c208dca35a078a4e5900ee38543108feefa07 | |
parent | d2105b10fe0f460c388fe4e09226313f519d8c00 (diff) |
[PATCH] x86_64: Revert k8-bus.c northbridge access change
As Travis Betak points out it accesses the wrong northbridge subfunction
now. Switch back to the old code.
Cc: "Travis Betak" <betak@mpdtxmail.amd.com>
Signed-off-by: Andi Kleen <ak@suse.de>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
-rw-r--r-- | arch/x86_64/pci/k8-bus.c | 10 |
1 files changed, 5 insertions, 5 deletions
diff --git a/arch/x86_64/pci/k8-bus.c b/arch/x86_64/pci/k8-bus.c index b50a7c7c47f8..3acf60ded2a0 100644 --- a/arch/x86_64/pci/k8-bus.c +++ b/arch/x86_64/pci/k8-bus.c | |||
@@ -2,7 +2,6 @@ | |||
2 | #include <linux/pci.h> | 2 | #include <linux/pci.h> |
3 | #include <asm/mpspec.h> | 3 | #include <asm/mpspec.h> |
4 | #include <linux/cpumask.h> | 4 | #include <linux/cpumask.h> |
5 | #include <asm/k8.h> | ||
6 | 5 | ||
7 | /* | 6 | /* |
8 | * This discovers the pcibus <-> node mapping on AMD K8. | 7 | * This discovers the pcibus <-> node mapping on AMD K8. |
@@ -19,6 +18,7 @@ | |||
19 | #define NR_LDT_BUS_NUMBER_REGISTERS 3 | 18 | #define NR_LDT_BUS_NUMBER_REGISTERS 3 |
20 | #define SECONDARY_LDT_BUS_NUMBER(dword) ((dword >> 8) & 0xFF) | 19 | #define SECONDARY_LDT_BUS_NUMBER(dword) ((dword >> 8) & 0xFF) |
21 | #define SUBORDINATE_LDT_BUS_NUMBER(dword) ((dword >> 16) & 0xFF) | 20 | #define SUBORDINATE_LDT_BUS_NUMBER(dword) ((dword >> 16) & 0xFF) |
21 | #define PCI_DEVICE_ID_K8HTCONFIG 0x1100 | ||
22 | 22 | ||
23 | /** | 23 | /** |
24 | * fill_mp_bus_to_cpumask() | 24 | * fill_mp_bus_to_cpumask() |
@@ -28,7 +28,8 @@ | |||
28 | __init static int | 28 | __init static int |
29 | fill_mp_bus_to_cpumask(void) | 29 | fill_mp_bus_to_cpumask(void) |
30 | { | 30 | { |
31 | int i, j, k; | 31 | struct pci_dev *nb_dev = NULL; |
32 | int i, j; | ||
32 | u32 ldtbus, nid; | 33 | u32 ldtbus, nid; |
33 | static int lbnr[3] = { | 34 | static int lbnr[3] = { |
34 | LDT_BUS_NUMBER_REGISTER_0, | 35 | LDT_BUS_NUMBER_REGISTER_0, |
@@ -36,9 +37,8 @@ fill_mp_bus_to_cpumask(void) | |||
36 | LDT_BUS_NUMBER_REGISTER_2 | 37 | LDT_BUS_NUMBER_REGISTER_2 |
37 | }; | 38 | }; |
38 | 39 | ||
39 | cache_k8_northbridges(); | 40 | while ((nb_dev = pci_get_device(PCI_VENDOR_ID_AMD, |
40 | for (k = 0; k < num_k8_northbridges; k++) { | 41 | PCI_DEVICE_ID_K8HTCONFIG, nb_dev))) { |
41 | struct pci_dev *nb_dev = k8_northbridges[k]; | ||
42 | pci_read_config_dword(nb_dev, NODE_ID_REGISTER, &nid); | 42 | pci_read_config_dword(nb_dev, NODE_ID_REGISTER, &nid); |