thermal: add available policies sysfs attribute
The Linux thermal framework support to change thermal governor policy in userspace, but it can't show what available policies supported. This patch adds available_policies attribute to the thermal framework, it can list the thermal governors which can be used for a particular zone. This attribute is read only. Signed-off-by: Wei Ni <wni@nvidia.com> Reviewed-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/thermal/sysfs-api.txt6
1 files changed, 6 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index c1f6864a8c5d..10f062ea6bc2 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -180,6 +180,7 @@ Thermal zone device sys I/F, created once it's registered:
180 |---temp: Current temperature 180 |---temp: Current temperature
181 |---mode: Working mode of the thermal zone 181 |---mode: Working mode of the thermal zone
182 |---policy: Thermal governor used for this zone 182 |---policy: Thermal governor used for this zone
183 |---available_policies: Available thermal governors for this zone
183 |---trip_point_[0-*]_temp: Trip point temperature 184 |---trip_point_[0-*]_temp: Trip point temperature
184 |---trip_point_[0-*]_type: Trip point type 185 |---trip_point_[0-*]_type: Trip point type
185 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point 186 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
@@ -256,6 +257,10 @@ policy
256 One of the various thermal governors used for a particular zone. 257 One of the various thermal governors used for a particular zone.
257 RW, Required 258 RW, Required
258 259
260available_policies
261 Available thermal governors which can be used for a particular zone.
262 RO, Required
263
259trip_point_[0-*]_temp 264trip_point_[0-*]_temp
260 The temperature above which trip point will be fired. 265 The temperature above which trip point will be fired.
261 Unit: millidegree Celsius 266 Unit: millidegree Celsius
@@ -417,6 +422,7 @@ method, the sys I/F structure will be built like this:
417 |---temp: 37000 422 |---temp: 37000
418 |---mode: enabled 423 |---mode: enabled
419 |---policy: step_wise 424 |---policy: step_wise
425 |---available_policies: step_wise fair_share
420 |---trip_point_0_temp: 100000 426 |---trip_point_0_temp: 100000
421 |---trip_point_0_type: critical 427 |---trip_point_0_type: critical
422 |---trip_point_1_temp: 80000 428 |---trip_point_1_temp: 80000